384V 100AH PowerRack Lithium Battery Cabinet
  • 384V 100AH PowerRack Lithium Battery Cabinet
  • 384V 100AH PowerRack Lithium Battery Cabinet
  • video

384V 100AH PowerRack Lithium Battery Cabinet

Brand : EnrSaver

Product origin : China

Delivery time : 10-30day

Supply capacity : 5000 Pcs/Day

● Capable of High-Powered Emergency-Backup and Off-Grid Functionality
● Highest Efficiency Thanks to a Real High-Voltage Series Connection
● The Quick Plug Connector Design Quick Wiring and Allows for Maximum Flexibility and Ease of Use
● Grand A Lithium Iron Phosphate (LFP) Battery: Maximum Safety, Life Cycle, and Power
● Compatible With Leading High Voltage Battery Inverters
● Highest Safety Standards
● The 384V LiFePO4 battery modules can be customized, also 100Ah and 200Ah capacity.

Download

384V 100AH PowerRack Lithium Battery Cabinet

1、Scope of application documents

The specification of this product is only applicable to the protection parameters of a rechargeable lithium-ion battery Product and cell designed by Foshan EnrSaver New Energy Technology Co., Ltd.

 

2、The Specification Amendment

If the raw materials, production processing, production system or battery usage environments & other conditions need to be changed, the amendment side needs provide the written advice to the other side, only the both sides come to agreement, the amendment will be effective.

 

3、Product or Cell testing conditions

It is recommended to use newly produced battery packs and new cells for related tests.Unless specified, testing and measurement shall be done under temperature of 20±5℃ and relative humidity of 45~75%.

 

4、Standard

4.1 Reference Standard GB 31241-2014 UL1642

GB/T 31486-2015

GB/T 31485-2015

GB/T 31484-2015

4.2 Measuring Instrument and Apparatus

.1 Dimension Measuring Instrument

The dimension measurement shall be implemented by instruments with equal or more precision scale of 0.02mm.

 

.2 Voltmeter

Standard class specified in the national standard or more sensitive class having inner impedance more than 10kΩ/V

 

.3 Ammeter

Standard class specified in the national standard or more sensitive class. Total external resistance including ammeter and wire is less than 0.01Ω.

 

.4 Impedance Meter

Impedance shall be measured by a sinusoidal alternating current method(1kHz LCR meter).

 

4.3 Testing Conditions (Unless Specially Requirements) Atmosphere Pressure : 86~106kPa Temperature:20℃±5℃

Relative Humidity:≤75%

5. Main specifications (IFP23140160-100Ah )

 

5.1 Cell Battery specifications

N

o

Item

General Parameter

Remark

 

1

 

Rated Capacity

Typical

100Ah

 

Standard discharge after Standard charge

Minimum

100Ah

2

Nominal Voltage

3.2V

Mean Operation Voltage

 

3

 

Internal Impedance

 

≤0.4mΩ

Under 20±5℃ Environment Temperature , the Usage Frequency  of  Fully  Charge( 1KHz) , Use AC Internal Impedance test machine to test

 

4

 

Standard charge

Constant Current 0.5C5A Constant Voltage 3.6V

0.02C5A cut-off

Charge time : Approx2.5h

 

5

 

Rapid Charge

Constant Current 1C5A Constant Voltage 3.6V

0.02C5A cut-off

Charge time : Approx1.5h

 

6

Standard Charge Cut-off Voltage

 

3.6V

Voltage of the battery when the Charge

is stopped

 

7

Standard Discharge Cut-off Voltage

 

2.5V

Voltage  of the battery when the discharge is stopped

8

Standard discharge

Constant current 1C5A end voltage 2.5 V

100A

9

Maximum discharge current

Constant current:1C5A end voltage:2.5 V

100A@≧0℃

 

10

 

Dimension

Thickness:48±0.5mm

 

Initial Dimension

Width:173.9±0.8mm

Height:120.6±0.8mm

11

Weight

2300g±0.05kg

APPROX

 

12

 

Operating Temperature Range

 

Temperature:-20~60℃ Humidity: ≤65%RH

Recommended charge/discharge current≤ 1I1 (50A),when cell temperature is lower than0℃, Recommended cool the cell, when cell temperature is higher than 60℃

13

Storage Temperature

Range

-20℃ ~25℃

Recommend( 25±3℃ );≤90%RH storage

moisture range.

5.1 Battery Pack specifications for single module 48V 100AH

 

No

Item

General Parameter

Remark

1

Combination method

15S1P


2

Rated Capacity

Typical

100Ah

Standard discharge after Standard charge

package)

Minimum

98Ah

3

Factory Voltage

48V-50.5V

Mean Operation Voltage

4

Voltage at end of

Discharge

<=40.5V

Discharge Cut-off Voltage

5

Charging Voltage

54.6V


 

6

 

Internal Impedance

 

≤100mΩ

Under 20±5℃ Environment Temperature , the Usage Frequency of Fully

Charge( 1KHz) , Use AC Internal Impedance

test machine to test

 

7

 

Max Charging Current(Icm)

 

120A

Ampere-meter ,Maximum allowable charging current of the battery pack

 

8

 

Limited Charging Voltage(Ucl)

 

54.6V

 

Volta-meter (Serial*3.6V) ,Battery pack safe charging voltage

9

Max Discharging current

120A

Maximum discharge current allowed by the battery pack

 

10

Discharge Cut-off voltage(Udo)

 

40.5V

Voltage of the battery when the discharge is stopped

 

11

 

Operation Temperature Range

Charge:0~55℃


Discharge: -20~60℃

 

12

 

Storage Temperature Range

 

-20℃~25℃

Recommend(25±3℃);≤90%RH storage

moisture range.

 

13

Single module Size/weight

480*442* 220mm /45Kg

1PCS of Module weight 45kg

Main control box size/weight

/

/


5.3 384V 100AH battery cabinet specifications

No

Item

General Parameter

Remark

1

Combination method

PACK*8

8 sets of modular (48V 100AH) connect in series

2

Rated Capacity

384V/100AH

Standard discharge after Standard charge

package)

3




4

Factory Voltage

384V-400V

Mean Operation Voltage

5

Voltage at end of

Discharge

<=324V

Discharge Cut-off Voltage

6

Charging Voltage

436.8V

3.6V/cell

 

 

7

 

 

Internal Impedance

 

 

≤100mΩ

Internal resistance measured at AC 1KHZ after 50% charge

The measure must uses the new batteries that within one week after shipment and

cycles less than 5 times

8

Standard charge

standard

50A* number of parallel strings

9

Standard discharge

standard

100A* number of parallel strings

10

Maximum Continuous Charge

Current

standard

50A* number of parallel strings

11

Maximum Continuous Discharge Current

standard

100A* number of parallel strings

12

Operation Temperature Range

Charge:0~55℃


13


Discharge: -20~60℃


 

 

14

 

 

Storage Temperature Range

 

 

-20℃~25℃

 

Recommend(25±3℃);≤90%RH storage moisture range.

15

System size

8 modulars with size:

480*442* 220mm each


16

System weight

400KG



Responsibility
Social welfare
Company Style
Group Photo of Factory Staff
FAQ
Do you have a certificate?
All our products have certificates, mainly European certificates, CE, TUV, DEKRA, etc....more
Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy

close left right