384V 100AH PowerRack Lithium Battery Cabinet
Brand : EnrSaver
Product origin : China
Delivery time : 10-30day
Supply capacity : 5000 Pcs/Day
● Capable of High-Powered Emergency-Backup and Off-Grid Functionality
● Highest Efficiency Thanks to a Real High-Voltage Series Connection
● The Quick Plug Connector Design Quick Wiring and Allows for Maximum Flexibility and Ease of Use
● Grand A Lithium Iron Phosphate (LFP) Battery: Maximum Safety, Life Cycle, and Power
● Compatible With Leading High Voltage Battery Inverters
● Highest Safety Standards
● The 384V LiFePO4 battery modules can be customized, also 100Ah and 200Ah capacity.
Download
1、Scope of application documents
The specification of this product is only applicable to the protection parameters of a rechargeable lithium-ion battery Product and cell designed by Foshan EnrSaver New Energy Technology Co., Ltd.
2、The Specification Amendment
If the raw materials, production processing, production system or battery usage environments & other conditions need to be changed, the amendment side needs provide the written advice to the other side, only the both sides come to agreement, the amendment will be effective.
3、Product or Cell testing conditions
It is recommended to use newly produced battery packs and new cells for related tests.Unless specified, testing and measurement shall be done under temperature of 20±5℃ and relative humidity of 45~75%.
4、Standard
4.1 Reference Standard GB 31241-2014 UL1642
GB/T 31486-2015
GB/T 31485-2015
GB/T 31484-2015
4.2 Measuring Instrument and Apparatus
.1 Dimension Measuring Instrument
The dimension measurement shall be implemented by instruments with equal or more precision scale of 0.02mm.
.2 Voltmeter
Standard class specified in the national standard or more sensitive class having inner impedance more than 10kΩ/V
.3 Ammeter
Standard class specified in the national standard or more sensitive class. Total external resistance including ammeter and wire is less than 0.01Ω.
.4 Impedance Meter
Impedance shall be measured by a sinusoidal alternating current method(1kHz LCR meter).
4.3 Testing Conditions (Unless Specially Requirements) Atmosphere Pressure : 86~106kPa Temperature:20℃±5℃
Relative Humidity:≤75%
5. Main specifications (IFP23140160-100Ah )
5.1 Cell Battery specifications
N o | Item | General Parameter | Remark | |
1 |
Rated Capacity | Typical | 100Ah |
Standard discharge after Standard charge |
Minimum | 100Ah | |||
2 | Nominal Voltage | 3.2V | Mean Operation Voltage | |
3 |
Internal Impedance |
≤0.4mΩ | Under 20±5℃ Environment Temperature , the Usage Frequency of Fully Charge( 1KHz) , Use AC Internal Impedance test machine to test | |
4 |
Standard charge | Constant Current 0.5C5A Constant Voltage 3.6V 0.02C5A cut-off | Charge time : Approx2.5h | |
5 |
Rapid Charge | Constant Current 1C5A Constant Voltage 3.6V 0.02C5A cut-off | Charge time : Approx1.5h | |
6 | Standard Charge Cut-off Voltage |
3.6V | Voltage of the battery when the Charge is stopped | |
7 | Standard Discharge Cut-off Voltage |
2.5V | Voltage of the battery when the discharge is stopped | |
8 | Standard discharge | Constant current 1C5A end voltage 2.5 V | 100A | |
9 | Maximum discharge current | Constant current:1C5A end voltage:2.5 V | 100A@≧0℃ | |
10 |
Dimension | Thickness:48±0.5mm |
Initial Dimension | |
Width:173.9±0.8mm | ||||
Height:120.6±0.8mm | ||||
11 | Weight | 2300g±0.05kg | APPROX | |
12 |
Operating Temperature Range |
Temperature:-20~60℃ Humidity: ≤65%RH | Recommended charge/discharge current≤ 1I1 (50A),when cell temperature is lower than0℃, Recommended cool the cell, when cell temperature is higher than 60℃ | |
13 | Storage Temperature Range | -20℃ ~25℃ | Recommend( 25±3℃ );≤90%RH storage moisture range. |
5.1 Battery Pack specifications for single module 48V 100AH
No | Item | General Parameter | Remark | |
1 | Combination method | 15S1P | ||
2 | Rated Capacity | Typical | 100Ah | Standard discharge after Standard charge (package) |
Minimum | 98Ah | |||
3 | Factory Voltage | 48V-50.5V | Mean Operation Voltage | |
4 | Voltage at end of Discharge | <=40.5V | Discharge Cut-off Voltage | |
5 | Charging Voltage | 54.6V | ||
6 |
Internal Impedance |
≤100mΩ | Under 20±5℃ Environment Temperature , the Usage Frequency of Fully Charge( 1KHz) , Use AC Internal Impedance test machine to test | |
7 |
Max Charging Current(Icm) |
120A | Ampere-meter ,Maximum allowable charging current of the battery pack | |
8 |
Limited Charging Voltage(Ucl) |
54.6V |
Volta-meter (Serial*3.6V) ,Battery pack safe charging voltage | |
9 | Max Discharging current | 120A | Maximum discharge current allowed by the battery pack | |
10 | Discharge Cut-off voltage(Udo) |
40.5V | Voltage of the battery when the discharge is stopped | |
11 |
Operation Temperature Range | Charge:0~55℃ | ||
Discharge: -20~60℃ | ||||
12 |
Storage Temperature Range |
-20℃~25℃ | Recommend(25±3℃);≤90%RH storage moisture range. | |
13 | Single module Size/weight | 480*442* 220mm /45Kg | 1PCS of Module weight 45kg | |
Main control box size/weight | / | / | ||
5.3 384V 100AH battery cabinet specifications | |||
No | Item | General Parameter | Remark |
1 | Combination method | PACK*8 | 8 sets of modular (48V 100AH) connect in series |
2 | Rated Capacity | 384V/100AH | Standard discharge after Standard charge (package) |
3 | |||
4 | Factory Voltage | 384V-400V | Mean Operation Voltage |
5 | Voltage at end of Discharge | <=324V | Discharge Cut-off Voltage |
6 | Charging Voltage | 436.8V | 3.6V/cell |
7 |
Internal Impedance |
≤100mΩ | Internal resistance measured at AC 1KHZ after 50% charge The measure must uses the new batteries that within one week after shipment and cycles less than 5 times |
8 | Standard charge | standard | 50A* number of parallel strings |
9 | Standard discharge | standard | 100A* number of parallel strings |
10 | Maximum Continuous Charge Current | standard | 50A* number of parallel strings |
11 | Maximum Continuous Discharge Current | standard | 100A* number of parallel strings |
12 | Operation Temperature Range | Charge:0~55℃ | |
13 | Discharge: -20~60℃ | ||
14 |
Storage Temperature Range |
-20℃~25℃ |
Recommend(25±3℃);≤90%RH storage moisture range. |
15 | System size | 8 modulars with size: 480*442* 220mm each | |
16 | System weight | 400KG |
All our products have certificates, mainly European certificates, CE, TUV, DEKRA, etc....more