51.2V 100Ah Power Wall LiFePO4 Battery
Brand : EnrSaver
Product origin : China
Delivery time : 7-15day
Supply capacity : 10000 Pcs/Day
◆High-quality 51.2V 5kwh Wall Mounted LiFePO4 Battery, safety, deep cycle and long lifespan.
◆LCD monitor the energy storage power data and operating status.
◆Air cooling to improve the reliability of the product.
◆External main switch to reduce product power consumption and improve safety.
◆Wall brackets, which can meet the installation and use of different place.
◆BMS bulit inside, over-voltage, over-load, over-temperature protection, atc.
◆Compatible, can be connected to different types of loads within the voltage range.
Download
1. Scope
The specification shall be applied to LiFePO4 rechargeable battery pack Of 24140160-16S2P which is manufactured by Foshan EnrSaver New Energy Technology Co., Ltd.
2. Main specifications
2.1 Cell Battery specifications
Lithium Battery Cell | No. | Item | General Parameter | Remark | |
1 |
Rated Capacity | Typical | 100Ah | Standard discharge (0.2C5A) after Standard charge | |
Minimum | 100Ah | ||||
2 | Nominal Voltage | 3.2V | Mean Operation Voltage | ||
3 |
Internal Impedance |
≤0.4 mΩ | Internal resistance measured at AC 1KHZ after 50% charge The measure must uses the new batteries that within one week after shipment and cycles less than 5 times | ||
4 |
Dimension | Thickness: 48±0.5mm |
Initial Dimension | ||
Width:173.9±0.8mm | |||||
Height:120.6±0.8mm | |||||
5 | Weight | 2300g±0.05kg | APPROX | ||
6 |
Standard charge | Constant Current 0.5C5A Constant Voltage 3.6V 0.02C5A cut-off |
Charge time : Approx3.5h | ||
7 |
Rapid Charge | Constant Current 1C5A Constant Voltage 3.65V 0.01C5A cut-off | Charge time : Approx1.5h@≧10C | ||
8 | Standard discharge | Constant current 0.33C5A end voltage 2.5 V |
16.5A | ||
9 | Maximum discharge current | Constant current:2C5A end voltage :2.5 V |
100A@≧0C | ||
10 | Volumetric specific energy |
295 WH/L |
APPROX | ||
Gravimetric specific energy | 139WH/KG | APPROX |
2.2 Battery Pack specifications
Lithium Battery Package | No. | Item | General Parameter | Remark | |
1 | Combination method | 16S1P | |||
2 |
Rated Capacity | Typical | 100Ah | Standard discharge after Standard charge (package) | |
Minimum | 98Ah | ||||
3 | Factory Voltage | 51V-53V(40-60%) | Mean Operation Voltage | ||
4 | Voltage at end of Discharge |
40-44V |
Discharge Cut-off Voltage | ||
5 | Charging Voltage | 56-58V | |||
6 |
Internal Impedance |
≤60mΩ | Internal resistance measured at AC 1KHZ after 50% charge The measure must uses the new batteries that within one week after shipment and cycles less than 5 times | ||
7 |
Standard charge | Constant Current 20A Constant Voltage see No.5 0.02CA cut-off |
Charge time : Approx 6 h | ||
Limiting current | 20A | ||||
8 |
Standard discharge | Constant current:20A end voltage see NO.4 | |||
9 | Maximum Continuous Charge Current |
100A |
≥10ºC | ||
10 | Maximum Continuous Discharge Current |
100A | ≥10ºC | ||
11 | Operation Temperature Range | Charge: 0~45C | 60±25%R.H. Bare Cell | ||
Discharge: -20~55C | |||||
12 |
Storage Temperature Range | Less than 12 months : - 10~35C |
60±25%R.H. at the shipment state | ||
less than 3 months: - 10~45C | |||||
Less than 7 day : -20~65C | |||||
13 | Dimensions | 680*485*180 (220)mm | Include Bracket | ||
14 | Weight | Approx :70kg |
3. Battery Management System Specification
3.1 BMS function introduction
1): The BMS is designed for 15/16 series lithium battery.
2): The BMS have all functions which are :
overcharge detection function
over discharge detection function
over current detection function
short detection function
Temperature detection function)
balance function
communicate function
Alarm function
Total capacity function
Storage history function
3.2 BMS Protect parameter
Items | Details | Standard |
Cell overcharge protection | Overcharge detection voltage | 3.65± 0.025V |
Overcharge detection delay time | Typical:1.0s | |
Overcharge release voltage | 3.38± 0.02V | |
Cell over-discharge protection | Over-discharge detection voltage | 2.5± 0.02V |
Over-discharge detection delay time | Typical:1.0s | |
Over-discharge release voltage | 2.9± 0.02V or charge release | |
Over-current protection | discharge Over-current protection current1 | 130± 10A |
discharge Over-current detection delay time 1 | 1S | |
discharge Over-current protection current 2 | 150± 10A | |
discharge Over-current detection delay time 2 | ≤100m±50ms | |
Charge OC protection current | 130± 10A | |
Short protection | Short protection current | 350± 10A |
Protection condition | Load short | |
Detection delay time | ≤300us | |
Protection release condition | Charging release | |
Temperature(T) protection | Charge high T protection | 55± 3C |
Charge high T recover | 50± 5C | |
Discharge high T protection | 65± 5C | |
Discharge high T recover | 60± 5C | |
Charge low T protection | -5± 5C | |
Charge low T recover | 0± 5C | |
Discharge low T protection | -20± 5C |
Discharge low T recover | -15± 5C | |
Balance | Balance threshold voltage | 3.45V |
Communication | It has RS232 /RS485 and canbus standard communication interface, it can real-time monitoring the capacity of battery bank, the voltage, current, environment temperature, and charging/discharging current. | |
Alarm | It has over-temperature, over charge, under-voltage, over-current, short circuit alarm Function. |
4. Appearance and structural dimensions
There shall be no such defect as scratch, bur and other mechanical scratch, and the connector should be no rust dirt. The structure and dimensions see attached drawing of the battery.
Unit (mm) | |||||
L | 680 | W | 485 | H | 180 |
L | / | WIRE | / | Terminal | 8mm Easy Plug |
Remarks | Output cable: 35mm2,Length: 2m |
5. Case Structure of Battery Pack
Descriptions
No. | Description | Silk-screen | Remark |
1 | UES0600 | P+ P+ | Output terminal |
2 | UES0600 | P- P- | Output terminal |
3 | port Reset button | RST | For reset the batter |
4 | Dial switch | ADS | Set the address |
5 | Do | ||
6 | CANbus Port | CANbus | CANbus and inverter connection port |
7 | RS485A Port | RS485 | RS485 and inverter connection port |
8 | RS232 Port | RS232 | RS232 communication port |
9 | RS485B port | RS485 | RS485 parallel communication interface |
10 | LED | RUN | Operation indicator |
11 | LED | ALM | Alarm indicator |
12 | LED | CAPACITY | Capacity indicator |
13 | LCD | ||
14 | LCD Key | ||
15 | Switch | ||
16 | Bracket | ||
17 | Handle |
6. Connection mode for parallel communication
6.1 RS485 Parallel Communication
While in RS485 parallel communication, dial-up addresses of battery module are 1,2,3,4……14,15; By this method, we can be allowed to read each data depending on battery module. Any battery other than address 0 can be connected to the host computer; FF polling mode used as consulting mode.
Note: RS485 communication address can not be 0, the address set by the host computer is required to be the same as the battery communication address, do not have duplicate addresses, otherwise communication may be affected.
6.2 Address Switch function (Only in Parallel)
7. Battery test equipment
7.1 Dimension Measuring Instrument
The dimension measurement shall be implemented by instruments with equal or more precision scale of 0.1mm.
7.2 Voltmeter
Standard class specified in the national standard or more sensitive class having inner impedance not less than 10 KΩ/V.
7.3 Ammeter
Standard class specified in the national standard or more sensitive class. Total external resistance including ammeter and wire is less than 0.01Ω .
7.4 Impedance Meter
Impedance shall be measured by a sinusoidal alternating current method(AC 1kHz LCR meter).
8. Standard Test Condition
Test should be conducted with new batteries within one month after shipment from our factory and the cells shall not be cycled more than five times before the test. Unless otherwise defined, test and measurement shall be done under temperature of 23±2C and relative humidity of less
75%.,air 86Kpa~106Kpa.
Unless otherwise defined, 30min,rest period after charge,30min,rest period after discharge.
9. Storage and Others
9.1 Long Time Storage
If stored for a long time(don’t used,exceed three months), the cell should be stored in drying and cooling place. The cell’s storage voltage should be 51V-53V and the cell is to be stored in a condition that the temperature of 23±2C and the humidity 0f 45%- 75%. Long-term use of unused batteries to recharge every 3 months 。Ensure that the battery voltage is within the above range。
9.2 Others
Any matters that this specification does not cover should be conferred between the customer and ENRSAVER
10. Amendment of this Specification
This specification is subject to change with prior notice
All our products have certificates, mainly European certificates, CE, TUV, DEKRA, etc....more